and after a few minutes aux.heat on. can you tell me if its correct that the furnace work all the time?I dont’ have any manual for this furnace.Thank you very much for your help. Sincerely, Dana
Yankees Bedding MLB Comforter

How to Identify and Resolve Common Issues ?

We offer a diverse range of insights on identifying and resolving common problems in sports. Our sources encompass academic articles, blog posts, and personal essays shared by seasoned athletes. :

This style of Serial Number is formatted with four letters at the beginning of the sequence. The second letter is the month of manufacture and the third letter is the year of manufacture.
6 red colored flashes on your furnace means that the modulating gas valve has failed. This valve will need to be replaced. 7 red colored flashes signals to you that your furnace is in “lock out mode” . If after 3 attempts to re ignite is unsuccessful, “lock out mode” will remain in place for one-hour.
Code 1 = Flame sensed with no call for heat. ► In a Code 1 situation, the furnace control board thinks that the gas valve is stuck on and the flame is still burning without a call for heat. Therefore, when a control board goes into a code 1, it will lock the inducer motor and blower motor on.
You can determine the size in tons of your York HVAC system by examining the model number on the data sticker at the side of the a/c condenser (outdoor unit). Look for first two numbers in the model number. They are divisible by 6 or 12, which represent the nominal BTU of the system in thousands.
Find the model number. Within this string of letters and numerals, you should find an even, two-digit number. The possibilities on residential units range from 18 to 60. Divide the number by 12 (which represents 12,000 Btu/hr, or one ton of cooling capacity) to get your AC unit`s tonnage.
Clogged Filters

They capture impurities in the air that goes through the unit. They can get filled to capacity, however, which may prevent the system from providing adequate heating to your home. A blinking red light alerts you of the need to clean or replace your air filters.

If your furnace is flashing 2 times it likely means the furnace is blowing cold air. This is happening most likely because the furnace is unable to catch a flame.
To read a furnace error code, locate the LED light and note its blinking pattern. Be sure to count how many times the light flashes and to note how quickly it`s blinking. To determine what a particular light combination signifies, consult the installation guide for your particular furnace.
Description: Ten (10) character Serial number. Begins with one (1) letter digit followed by one (1) numerical digit, then another one (1) letter digit and ends with seven (7) numerical digits. Year of manufacture is 2nd-4th numerical digits combined. Month of manufacture is 3nd character, which is a letter digit.
First, if your furnace isn`t turning on, then the issue is with the power. Go to your circuit board and make sure the fuses aren`t cracked or blown. If it`s blown, replace it but otherwise resetting the circuit should do the trick. Another reason it might not be heating could be an issue with the thermostat.
Near the top of the nameplate you should see the manufacturer`s date as a month and year. (Sometimes the manufacturer`s date is abbreviated as MFR DATE.) If you find this, congratulations: you now know the “birth date” of your AC. Easy!
You can find out the age of your furnace by looking at the nine-digit model number. The first digit will be a letter. The second and third numbers will be the year, and the fourth and fifth numbers denote the week of the year the unit was made.
How can I tell the age of a York air conditioner or furnace from the serial number? For York systems manufactured from October 2004 to the present, the first and third characters in the serial number will be letters, and the second and fourth characters will be numbers that indicate the year of manufacture.
AC Model Numbers

There isn`t a universal model number decoder since AC manufacturers uses different codes, but the model number can tell you the capacity, tonnage, single/variable speed, voltage, refrigerant type, and brand name of your air conditioner.

The model and serial number can be found on the rating plate of your air conditioner or heat pump. This is generally found slightly above the refrigerant valves on the back side of the unit.
The model and serial number can be found on the rating plate of your air conditioner or heat pump. This is generally found slightly above the refrigerant valves on the back side of the unit.

Discover Relevant Questions and Answers for Your Specific Issue

the most relevant questions and answers related to your specific issue

I have a York Stellar model mid efficiency furnace Model # P?UCD12N07601A, Serial # EXAM3600524 installed in 1992. The HSI was replaced approximately 3 months ago. Over the last two weeks the ventor motor comes on, the HSI lights but does not ignite the gas. The ventor motor runns continously and the HSI continues to turn off and on without gas ignition. Some times by turning the ventor motor off and on (by opening and closing the bottom furnace faces panel door) will give be ignition after the HSI goes through 1-4 cycles. If I can’t get it to work I call my furnace repair guy. The serviceman thought it was the pressure switch and ordered one. Just this last weekend I had no heat and another service guy came in replaced the HSI again and adjusted the pressure switch and said this fix should work. Less than a day later furnace still experiencing the same problem-Ventor motor comes on, HSI comes on but no gas ignition. ventor motor runs continuously and the temperature in the house drops! I’m frustrated and the servicemen don’t seem to know how to fix the problem for good.
ANSWER : Make sure the vent pipes that exhaust the fumes are not blocked in any way and also check the drain line to be sure it is not kinked from the vent motor to the trap. Take the hoses off the vent motor and the pressure switch and make sure all the hoses are clean and free from debris also check the trap on the drain hose and make sure it has water in it if it doesn’t this will creat a negative pressure in the vent motor housing not allowing the vent pressure switch to make.

Read Full Q/A … : Yankees Bedding MLB Comforter

My swimming pool. I have just had my fifth IC 40 Intellichlor chlorine generator installed in 4 years at a cost of over $900 today. Each one has worked for no more than 8 months. The first three were replaces under three year warranty, the fourth by a factory rep and I bought the fifth today. The first three all failed with Flow Chk PCB error message. The fourth just stopped working on Sunday, no power or lights. A local Pentair warranty person, whom I paid a Service Call, unplugged the unit, opened the small power center cover, showed me the green light indicating that there was power, plugged in a new IC 40 which worked immediately (as did the other four). I asked if I should replace the power center and he said that it’s basically just a transformer and is working fine. We do get occasional power blips that make the clocks on microwaves, etc blink, but I thought that the power center essentially isolates the cell from these. I do have a Florida Power and Light surge protector on the electrical box that brings power into the house. I have now talked to the pool builder, two Pentair warranty repairmen and one factory rep. I am at a loss. They all tell me they have no idea why these units fail after less than a year. This last IC 40 was installed 3/24/2010, version 2.0 and now failed in less than 5 months. Should I replace the power center that the IC 40 plugs into. Any other suggestions. I have been told that this is the best chlorinator. I don’t want to keep replacing units. By the way, each unit had been spotless inside. I keep the water chemicals and salt levels at ideal levels. The units have never worked long enough to get dirty inside. The power center is connected to an Intellitouch control system outside with an indoor control panel. Last time I called Pentair North Carolina and got some smart alec tech person that had no suggestions. Please Help if you can.
ANSWER : I’ve had the same experiance. On my fifth one as well. Fail every year. No idea why.

Read Full Q/A … : Yankees Bedding MLB Comforter

Loud noise when furnace starts but furnace won’t come on.
ANSWER : Your fan delay relay has failed and must be replaced.

Read Full Q/A … : Yankees Bedding MLB Comforter

Suddenly stops recodring
ANSWER : I love my Sanyo mp3 recorder I’ve been using it in church for 4 or 5 years. It never quits it can hold an extra gig with a chip and i can plug it into my computer to upload it in seconds. I say replace the old recorder

Read Full Q/A … : Yankees Bedding MLB Comforter

I have a TX500, never been used (just out of the box) and had to get an electrician to my home for this problem. It will start rolling but quits in a few seconds. The electrician believes that it is a problem in the sensor that rides at the belt. There is only one sensor in the pulley; he thinks that perhaps there should be two as there is a hole placement opposite the one that is in there. When the belt quits, it goes to a number 3 on the board which he thinks is the sensor as well. If he is correct, where do we get another magnet to place there? If he is not correct, please offer help. We did not get a owners manual in the box and surely could use one; where can we get one? Please help…thankyou
ANSWER : Hello,I believe the best thing to do at this point is to look for a way to get the manual of the device, this will give a full guide and better understanding on how to fix this problem.Check maualnguide.com to search for the manual of the device, the link provides almost all manuals to all device.Take care.

Read Full Q/A … : Yankees Bedding MLB Comforter

I HAVE A YORK STELLAR PLUS,MODEL PEUDD12N09501C 15 YEARS OLD. THE AIR INDUCTION MOTOR RUNS FOREVER. THE AIR INDUCTION MOTOR COMES ON , THE THE THERMOSTAT CALLS FOR GAS, THE IGNITOR LIGHTS THE GAS, FURNACE HEATS UP AND THEN THE LIMITER SHUTS OFF THE GAS BEFORE THE BLOWER COMES ON AND THEN THE AIR INDUCTION MOTOR RUNS, AND RUNS TILL THE DUCT WORK IS VIBRATING. THEN OTHER TIME THE FURNACE WORKS RIGHT THROUGH THE HEAT CYCLE JUST LIKE IT WAS DESIGNED TO.
ANSWER : This flame is not likely going off on a high limit due to clogged filters as suggested previously because the unit goes off on safety before the blower comes on. If it works sometimes and not others it is most likely a flame sense issue or an electronic problem. If the boards logic tells the inducer to keep running if it thinks the flame is lost this may be your clue. You can attempt to find the red LED trouble light on the circuit board(or in burner compartment) and this may tell you exactly what the problem is but you may need to tape the door interlock switch so you don’t loose the code when you open the blower compartment. You can clean flame sensor with very fine sandpaper or steel wool but replacement is usually the best.

Read Full Q/A … : Yankees Bedding MLB Comforter

York manuals how does hvac zone york heating and
ANSWER : You can get the manual at york.com

Read Full Q/A … : Yankees Bedding MLB Comforter