fuse next to the slide in switch; mine doesn’t have one there. Is there another place I should look? I have power to the unit/relay.
Sport & Outdoor – Others

How to Identify and Resolve Common Issues ?

We offer a diverse range of insights on identifying and resolving common problems in sports. Our sources encompass academic articles, blog posts, and personal essays shared by seasoned athletes. :

We have had the same issue, the fuse is behind the cassette which you need to remove to gain access, if this fuse is intact it could be the 5 amp fuse in the electric box, this blew when we had a water pump issue and both the flush and water pump went off. Hope you get it fixed.
Usual cause of non flushing C250 / 260 is the impeller is jammed by black gunge. Black gunge is caused by using pink fluid in the flush tank and not draining. Fix is to remove the impeller / clean the impeller / drain the tank a couple of times by flushing (drain tube is too small for gunge to get out).
Just a little tip Myra, put the bathroom light on and press the flush button if the impeller is just stuck the light would dim a little,also in some cassette cupboards there`s a fuse in a holder at the rear base behind the tank.
If the valve in the electric valve is not closing when you release the button then water will continue to pass to the toilet flush. It is likely that you will need to replace the electric valve.
A clog is the most common reason for a toilet that doesn`t flush. Clogs can range in severity, from a complete blockage to a partial obstruction. Wipes, toilet paper and other items can build up in sewer lines, which could result in slow flushing that doesn`t completely clear the bowl.
If you have a toilet that doesn`t fully flush, common causes include a clog in the trap, a worn-out flapper, blocked rim jets, a faulty float, or an issue with the handle and chain.
Using the data sticker to identify your Thetford toilet model. If you are not sure which model toilet you have, you will find a data sticker attached to the base of the toilet beneath the waste holding tank. The model number will be printed at the beginning above the barcode – as shown below.
The fuse in the PSU is fine ,it’s the Thetford C262 unit ? the fuse is at the back of the waste container box.
In the case of a Thetford fridge: disconnect the orange wire from the fuse, which is located behind the lower ventilation grille outside (this may also be the solution if the fridge does not want to change its source).
Description. 2 x 3amp Fuse to suit Thetford cassette toilets.
In the case of a Thetford fridge: disconnect the orange wire from the fuse, which is located behind the lower ventilation grille outside (this may also be the solution if the fridge does not want to change its source).
Description. 2 x 3amp Fuse to suit Thetford cassette toilets.
If you have a toilet that doesn`t fully flush, common causes include a clog in the trap, a worn-out flapper, blocked rim jets, a faulty float, or an issue with the handle and chain.
There are a few different reasons why your toilet might be resisting your attempts to flush. It could be a blockage, it could be a problem with the flushing mechanics, it could be a water supply problem or it could simply be a broken handle.

Discover Relevant Questions and Answers for Your Specific Issue

the most relevant questions and answers related to your specific issue

My swimming pool. I have just had my fifth IC 40 Intellichlor chlorine generator installed in 4 years at a cost of over $900 today. Each one has worked for no more than 8 months. The first three were replaces under three year warranty, the fourth by a factory rep and I bought the fifth today. The first three all failed with Flow Chk PCB error message. The fourth just stopped working on Sunday, no power or lights. A local Pentair warranty person, whom I paid a Service Call, unplugged the unit, opened the small power center cover, showed me the green light indicating that there was power, plugged in a new IC 40 which worked immediately (as did the other four). I asked if I should replace the power center and he said that it’s basically just a transformer and is working fine. We do get occasional power blips that make the clocks on microwaves, etc blink, but I thought that the power center essentially isolates the cell from these. I do have a Florida Power and Light surge protector on the electrical box that brings power into the house. I have now talked to the pool builder, two Pentair warranty repairmen and one factory rep. I am at a loss. They all tell me they have no idea why these units fail after less than a year. This last IC 40 was installed 3/24/2010, version 2.0 and now failed in less than 5 months. Should I replace the power center that the IC 40 plugs into. Any other suggestions. I have been told that this is the best chlorinator. I don’t want to keep replacing units. By the way, each unit had been spotless inside. I keep the water chemicals and salt levels at ideal levels. The units have never worked long enough to get dirty inside. The power center is connected to an Intellitouch control system outside with an indoor control panel. Last time I called Pentair North Carolina and got some smart alec tech person that had no suggestions. Please Help if you can.
ANSWER : I’ve had the same experiance. On my fifth one as well. Fail every year. No idea why.

Read Full Q/A … : Sport & Outdoor – Others

I have purchased three 750-watt power inverters in the last three weeks. They have all failed to work on the second or third use. The first two were the same brand. I replaced an old one that ran for several years. I am using it to run a 4.7 amp 120-volt vacuum cleaner motor that pumps up my air dock. I have it connected directly with marine cable to one of the boat batteries. The battery outputs about 12.8 volts DC. The fuses don?t blow, just No Output. I am using a three-wire 120-volt extension cord and am, wired neutral, hot and ground to the AC motor vial an on/off switch. The motor works fine when I run house power with an extension cord from the dock next to me. Could I be, just unlucky with new inverters and need to buy a forth one?
ANSWER : The problem may be that the inverter is undersized for the load. Is the 4.7 Amp rating the motor peak draw or the nominal one. What I mean is that it takes many times more power to start start the motor than when the motor is running. Typically it is 3 to 7 times more amps to start the motor than when it is running. It could be that starting the vacumm cleaner is stressing the inverter and it is causing it to fail prematurely. If you can find out the locked rotor current draw of the motor, the that would be the mininum size of the inverter.

Also, the type of inverter will make a difference on how the motor operates. A modified sine wave will make the motor run hotter than a pure sine wave inverter. Hope this helps.

Read Full Q/A … : Sport & Outdoor – Others

I have a Kohler Condidant 5 Generator that will run as long as you hold the start button in. It dies when you let off. I have a harness for the remote switch but no switch – It also will start the generator when you cross the red and black wire and run as long as you hold them together. There are 3 wires to the main switch and 5 to the remote switch. Does the starter stay engaged the whole time you hold the start switch or does the computer release the starter once it is running? The Generator is producing electricity because I tested it while holding the start button. Some where is a wire that shold tell it to keep running. I have read online many descriptions of the same problem, most are told the board is bad so they replace it and still have the problem. Have not found a solution. Talked to a marine machanic today and he said he fixed his friends generator doing the same thing by running a bypass wire but he couldnt remember exactly what he did it was a long time ago. Can anyone help me. Thank you
ANSWER : The problem is either the ballast resistor or the starter bypass relay. The bypass relay should be part of the starter solenoid. I’m afraid I can’t tell you exactly where the ballast resistor is located. It should be a physically fairly large resistor made of ceramic. It should be retangular roughly 1.5″-3″ long and 3/8″-1/2″ accross with a wire on each end. It could also be a coil of wire mounted on a phenolic board.
If you need more help just add a comment and I’ll respond as soon as I get the message.

Read Full Q/A … : Sport & Outdoor – Others

I have a code 88 on my intex 8110. I have followed the directions for setup out of the standby mode. However, when I push the down button for a couple of seconds there is no short beep to prompt me to push the up button for a couple of seconds to start the programming mode. When I do push the up button, it has a fast pace, nonstop beeping as long as I have the button pushed. This was not a problem I had last year when I used it.
ANSWER : Code 88 – Startup/Standby for Intex 8110.Try hold down the left button for almost 6 seconds until it “beeps”, then
hold down right button for about 6 seconds until next “beeps”. That
should unlock the keypad.I hope this helps. Thank you and good luck!

Read Full Q/A … : Sport & Outdoor – Others

Need the wire diagram to rewire my Ariens lawnmover to bypass the safety switch. It is Ariens GT-19 model # 931026 Serial # 001463.
Can you help? It is an old Ariens mower but still runs good but now I need to bypass the safety switch in order to run it any longer. The local Ariens dealer said I need to go through the internet and get the wire diagram as they cannot give it to me directly. They told me I needed the wire diagram and the part involved in bypassing the safety switch. Hope this is all the information you need to help me.

Thank you. Roger Fielitz

ANSWER : Here is owner manual:http://apache.ariens.com/manuals/030305C.pdfusually the switch is behind the ignition, sometimes at the N position of gearshift, just look for a switch with one wire coming in & one going out (usually the same color); disconnect the two wires & jumper them together to bypass the switch. Looks like yours has one under the seat.

Read Full Q/A … : Sport & Outdoor – Others

Razor E-100 – The toggle switch was broken, I replaced it with another lighted switch, but the switch won’t light. The motor runs o.k., why won’t the switch light when turned on? Thanks.
ANSWER : The Switch can be almost any but the lighted switch has to be a compatible 24vdc lighted switch.
As seen on this web page.

SWT-105

Razor E100 and E125 Electric Scooter Parts ElectricScooterParts com

Read Full Q/A … : Sport & Outdoor – Others

Browning Hi-Power slide freezing
ANSWER : This problem may be related to the magazine . try another one and see if it still happens. The nagazine spring may be too weak to get the last round up high enough to feed into the chamber before the slide comes ahead

Read Full Q/A … : Sport & Outdoor – Others