new trigger switch for it and was told that their is a pretty specific spot for it to go. My problem is where does it go
Sport & Outdoor – Others

How to Identify and Resolve Common Issues ?

We offer a diverse range of insights on identifying and resolving common problems in sports. Our sources encompass academic articles, blog posts, and personal essays shared by seasoned athletes. :

If your STIHL chainsaw is going to have a problem, it`s likely to be with a worn carburetor, bad spark plugs, loose fuel hoses, or clogged fuel lines. You should also inspect the fuel intake system and ensure that there are no compression issues.
The carburetor might be clogged. A clogged carburetor is often caused by leaving fuel in the chainsaw for a long period of time. Over time, some of the ingredients in the fuel may evaporate, leaving behind a thicker, stickier substance. This sticky fuel can clog up the carburetor and cause the chainsaw engine to stall.
A spark plug might be defective and needs to be replaced.

If your chainsaw has a defective spark plug, it cannot create an electrical current to ignite the system. Remove the spark plug and inspect if it is dirty, cracked, eroded, or damaged. There may also be a heavy carbon buildup or a burned-up electrode.

If your non-starting chainsaw is electric

If you have an electric chainsaw that won`t start, first make sure that the power cable is connected to the mains, then check whether the cable and plug are damaged. If they aren`t, the problem could lie in the motor which, for example, may have worn or damaged brushes.

If your chainsaw still starts and then stops working, check the air filter. Clean or replace the air filter if it is dirty or damaged. Another reason that your chainsaw starts and then stops working could be that the spark arrestor is dirty or clogged. If this is the case, clean it with a wire brush.
The fuel line may be clogged from stale fuel deposits, more reasons to cause your chainsaw to cut out when applying throttle. If a fuel line is cracked, it will leak gasoline and draw air from outside into the fuel line. If the line is leaking fuel, it needs to be replaced.
The innovative STIHL Easy2Start™ makes starting STIHL power tools easy and straight forward, without requiring a lot of effort. STIHL power tools with STIHL Easy2Start™ are indicated by the letter “E” in the model name.
The STIHL Easy2Start™ system makes starting STIHL outdoor power tools almost effortless, eliminating the need for a strong pull of the starting cord. This advanced starting system is designed to make starting STIHL products easier.
This switch breaks the flow of current through the primary coil and causes a voltage spike (of perhaps 200 volts). The secondary coil, having 100 times more turns than the primary coil, amplifies this voltage to approximately 20,000 volts, and this voltage feeds to the spark plug.
For example, a STIHL MSA 120 C-B chainsaw with the recommended AK 20 battery lasts for up to 40 minutes or can achieve a battery life of up to 55 minutes when equipped with an AK 30 battery.
We hate to inform you, but gas chainsaws with automatic electric-start systems don`t exist. The mechanism that keeps the saw running—the gas engine—is the same mechanism that gives it the power to start. A special spring is probably the most common easy-start feature you`ll find on chainsaws.
With electric chainsaws, there are no fuel filters to change, no fuel tanks to clean, and no fuel and oil to mix before use. Simply keep the bar oil filled and the chain sharp and tensioned, and you`re good to cut.
How long the chainsaw runs before dying depends on how badly clogged the air filter is. In the case that your chainsaw runs for a while, then dies, it may be possible to simply clean the air filter to correct this symptom. However, a damaged air filter should be replaced.
This could be a number of things and is most likely fuel or storage related. Over a short period of time, fuel will become stale. If the unit is stored with stale gasoline, the system will become clogged or restricted. Fuel related failures are not warranty.
If your electric or gas saw`s chain won`t turn around the bar, chances are that the chain brake is stuck. On some saws, resetting the chain brake is as simple as pushing in on the side cover of the saw`s body with one hand, and pushing the chain brake forward while grabbing the top handle with the other.
Check the Fuel Flow

If you`re dropping power under load and your air systems are clean, then somewhere gas is leaking from the system. You`ll want to start at the tank, checking the vent hole on the tank to make sure it`s not plugged.

To check if the ignition module is getting voltage, set the multimeter to AC voltage (VAC) reading and check for voltage at the thermostat input or 24VAC input to the Ignition Control Module. You should get a reading of 24VAC with respect to common or ground.
An ignition issue can be caused by a faulty or failing ignition coil, spark plug, or spark plug wire set. These critical components of your ignition system keep your engine running smoothly.
Although “diagnosable engine management systems” are installed in today`s vehicles, a multimeter or oscilloscope must be used when checking ignition systems.
A dirty carburetor, bad gasoline and low-quality two-stroke oil that creates deposits all contribute to chainsaw starting problems.
Smart Start is one of Husqvarna`s unique technology because when their chainsaws are installed with it, it means it`s extremely easy to start. No more trying to crank it until you get tired of it.
STIHL Inc. manufactures approximately 80 models of handheld tools using U.S. and global materials. STIHL`s Virginia Beach facility includes 16 different assembly lines, on which approximately 275 different product variants are manufactured. STIHL Inc.
Unlike carbon brushes, the magnets in a brushless motor don`t need physical contact with other components to transmit a charge, so there`s less interference from friction. For greater efficiency in your cordless chainsaw, look for a saw with a brushless motor.
In a gas-powered chainsaw, the on/off switch stops the engine running by preventing the ignition coil from firing. This switch is also called kill switch. It must be clearly marked with the stop position.

Discover Relevant Questions and Answers for Your Specific Issue

the most relevant questions and answers related to your specific issue

I bought a new mossberg 590 a1 shot gun a month ago, I love the gun but its having a couple of problems, the first problem is that when shooting every once in a while i get sprayed in the face with exuast from shooting through the safety very scary! any ideas whats causing this? how to fix it? second is that some times the fireing pin sticks and the gun will not discharge a round? the third problem is that i have had feeding issues with gun where it will not realice a gound from the tube, ive taken a tip of a knife to the stuck round in the tube and it prys out with little effort, these problems dont happen every time i go shooting, just every once in a while, but they a happening more and more, im conserned cause the gun is brand new, and i wanna be safe while shooting, can you guys help me? any ideas/solutions? please help!!!!!!!
ANSWER : Personally, with that many problems, I’d call Mossberg and get a return authorization. None of these things should be happening, especially with a new gun.

Read Full Q/A … : Sport & Outdoor – Others

Spark plug wire boot grounding out on coil, 96 outback 2.5 automatic, just put new spark plug wires, new spark plugs, and new coil on. ran great for two weeks, now spark is jumping out of boot at coil on one wire, put old coil back on and still does it in the same spot. replaced wires again, and still does it in the same spot. seems to do it only under a load. Is my new spark plug on that cylinder bad? Does the coil need some insulation under it? It is the coil that sits right on top of the motor. Any ideas? thanks.
ANSWER : Sparks are high voltage, and will always follow the path of least resistance. If you can visibly see a spark (whether in a lighted area, or in the dark), that means either that a plug wire (or coil wire) is open (non conductive), or your have a carbon track on the surface where the spark can be seen, but most likely you have BOTH problems!

If you have an ohmmeter, check the resistance of each wire involved, particularly spark plug wires … which means you must be able to connect to both ends of each wire at the same, and hopefully, FLEX those wires, to be sure they don’t have a break inside that is intermittent (comes and goes)!

Read Full Q/A … : Sport & Outdoor – Others

3 year old Toro Z4200 time cutter Z, 19 HP Kohler, engine runs great, new battery, new solenoid, with the seat sensor connected or by-passed, STILL WONT start off the key switch. Clicks at the kill relay. Would the kill relay be the problem?
Whats confusing is, both the green and blue posts on the solenoid have 14.01 volts when you turn the key to ‘start’ position. Did the same thing with the old solenoid, which is probably still good. I replaced it to eliminate that variable. It also ‘clicks’ at the fuel switch at the carburetor bowl, but that is only 1 lead (I assume a hot lead) so Im thinking that CANT be it.
Using the old hillybilly method, jumping across the 2 top posts on the solenoid, with the key in on position, it will start right up, run, drive and mow just fine.
So my best guess is this ‘KILL RELAY’ must be bad?
Any help would be appreciated, thank you !
ANSWER : These things are pre requisites for engine cranking: PTO/Blades are off/button pushed down, the steering arms are out/parked position, and you are in the seat. I think. Definitely the blades have to off.

Read Full Q/A … : Sport & Outdoor – Others

Need the wire diagram to rewire my Ariens lawnmover to bypass the safety switch. It is Ariens GT-19 model # 931026 Serial # 001463.
Can you help? It is an old Ariens mower but still runs good but now I need to bypass the safety switch in order to run it any longer. The local Ariens dealer said I need to go through the internet and get the wire diagram as they cannot give it to me directly. They told me I needed the wire diagram and the part involved in bypassing the safety switch. Hope this is all the information you need to help me.

Thank you. Roger Fielitz

ANSWER : Here is owner manual:http://apache.ariens.com/manuals/030305C.pdfusually the switch is behind the ignition, sometimes at the N position of gearshift, just look for a switch with one wire coming in & one going out (usually the same color); disconnect the two wires & jumper them together to bypass the switch. Looks like yours has one under the seat.

Read Full Q/A … : Sport & Outdoor – Others

This is the izh 513m .177 rifle. It’s brand new. I am not sure as of what to do and the hammer want budge and the trigger won’t pull. The barrel has no tension and it won’t go up like its supposed to.
ANSWER : This could be a factory safety that the hammer and trigger do not move while in the cocked position. The barrel may be locking down purposely. Look near the spring or in the path of the barrel where it folds back up and look for a release button. What do you see?

Read Full Q/A … : Sport & Outdoor – Others

Mar 12, 2010 – Could it be the check valve? I took it off and the flap appears to be working correctly. This well has been here a long time. Never given me any problems. I do have galvenized couplers on the discharge and intake sides. Old. Could these be leaking even though they show no sign of water? The discharge is able to hold 30 pounds easily overnight. I do not hear any vacuum in the intake when I take it off. Could the pipe to the well have a leak? I know I would have to insert a sleeve bnut I do not want to go through the hassle if I do not have to. I had put on a brand new pump from the hardware store that did the same thing so I think that would elliminate the pump as being the problem.
Mar 12, 2010 – I have a 3/4hp flotec convertible jet pump. It is able to hold 30lbs pressure on the discharge side as the primie easily for 24 hours. It is not able to pull water from the well whcih has been here for years. i disconnected it for the winter and rehooked it up. The galvanized couplers on the discharge and pump side are old but do not appear to be leakeing as I taped them well. The check valve seems to be functioning well as I took it off and the flap works correctly. The well is not pulling watrer. there does not appear to be a vacuum on the check vale when I losen it. could the check valve be bad? I am aware I might have to resleeve the well, but do not want to hassle with this if I do not have to. I want to eliminate everything else first. i put another brand new pump on it to see if it was that. That partiuclar pump which was the same thng did not work either.

See less

ANSWER : Your well has gone dry it seems. It has happened to my before. At first the new pump I purchased that did not pump I took back for exchange and still no water. I finally gave in and called the well experts and I was told the well was dried up

Read Full Q/A … : Sport & Outdoor – Others

I have a York Stellar model mid efficiency furnace Model # P?UCD12N07601A, Serial # EXAM3600524 installed in 1992. The HSI was replaced approximately 3 months ago. Over the last two weeks the ventor motor comes on, the HSI lights but does not ignite the gas. The ventor motor runns continously and the HSI continues to turn off and on without gas ignition. Some times by turning the ventor motor off and on (by opening and closing the bottom furnace faces panel door) will give be ignition after the HSI goes through 1-4 cycles. If I can’t get it to work I call my furnace repair guy. The serviceman thought it was the pressure switch and ordered one. Just this last weekend I had no heat and another service guy came in replaced the HSI again and adjusted the pressure switch and said this fix should work. Less than a day later furnace still experiencing the same problem-Ventor motor comes on, HSI comes on but no gas ignition. ventor motor runs continuously and the temperature in the house drops! I’m frustrated and the servicemen don’t seem to know how to fix the problem for good.
ANSWER : Make sure the vent pipes that exhaust the fumes are not blocked in any way and also check the drain line to be sure it is not kinked from the vent motor to the trap. Take the hoses off the vent motor and the pressure switch and make sure all the hoses are clean and free from debris also check the trap on the drain hose and make sure it has water in it if it doesn’t this will creat a negative pressure in the vent motor housing not allowing the vent pressure switch to make.

Read Full Q/A … : Sport & Outdoor – Others